Josef Frisch (SLAC)15/09/2015, 09:00Time Resolved Diagnostics and SynchronizationTutorialThis is an overview of beam arrival time measurement techniques for FELs and other accelerators requiring femtosecond timing. This talk will present the trade-offs between the various techniques used at different facilities.Go to contribution page
-
Patrick Krejcik (SLAC)15/09/2015, 10:10Machine Parameter MeasurementsContributed OralMonitoring the pulse by pulse output intensity and profile of an FEL is a critical measurement both for users and for optimising the accelerator drive beam. The diagnostic challenge is to find a technique that is not susceptible to damage at high output power, is noninvasive and can be performed at high repetition rates. Fluorescent screens are invasive, susceptible to damage and limited in...Go to contribution page