Mr Tadeusz Kozielewski (Jülich Centre for Neutron Science, Forschungszentrum Jülich GmbH, Jülich, Germany)29/11/2017, 16:30A Neutron Spin-Echo Spectrometer (NSE) measures small velocity changes at a sample of the neutrons encoded by the neutrons spin clock while the neutron spin precesses in large magnetic fields following Bloch's equation. In order to reach this ambitious goal, a high precision of the magnetic field integral before and after the sample, which directly relates to the resolution of the...Go to contribution page
-
Mr Guido Vehres (Forschungszentrum Jülich GmbH)29/11/2017, 16:36Operations, User Support & MaintenanceAbstract for the 6th Design and Engineering of Neutron Instruments Meeting 2017, Sydney, November 29th – December 1st 2017 Commissioning of a shearing machine for soft matter samples H.Feilbach, B.Gold, W. Pyckhout-Hintzen, G. Vehres Jülich Centre for Neutron Science, Forschungszentrum Jülich GmbH, Jülich, Germany A. Radulescu Jülich Centre for Neutron Science, Forschungszentrum...Go to contribution page
-
Mr Scott Olsen (ANSTO)29/11/2017, 16:42Operations, User Support & MaintenanceOn 3 July 2017 ANSTO went live with a major new system known as SAP Ae (Ansto Enterprise). This one stop shop covers all aspects of asset management planning, including procurement, maintenance, calibration, asset renewal, customer relationships and even HR. This system has been primarily designed for the commercial side of ANSTO (Nuclear Medicines, Silicon Irradiation and Minerals divisions)....Go to contribution page
-
Mr Stewart Pullen (ANSTO)29/11/2017, 16:48Neutron Guides & ShieldingOral PresentationAs part of the transfer of the BioRef instrument from Helmholtz Zentrum Berlin (HZB) to ANSTO, Sydney, a number of lead shielding components will need to be lifted in and out of their positions. These lifts utilise RAMPA Type B inserts embedded in the lead shielding via a self-tapping process with a pilot hole. These inserts have been used extensively at other facilities and there is data on...Go to contribution page
-
Mr David Federici (Electrical controls Technician)29/11/2017, 17:04Operations, User Support & MaintenanceSafety Interlock System and User Interfaces My poster will be on the safety interlock system (SIS) employed at the ACNS, focusing on the interfaces including the touch screens we use to operate the safety system for an instrument. The touch screen interface design satisfies the needs of various users: 1. Instrument users require very clear and basic instructions to operate the...Go to contribution page
-
Kristian Veronika (ANSTO)29/11/2017, 17:10During the 2019 major shutdown, ANSTO has set up a project to remove existing Thermal Neutron Guide (TG1-3) in-pile assembly and replace it with a new in-pile assembly containing an additional TG-2 A/B in-pile guides. The purpose of this presentation is to provide following: - Brief description of ANSTO neutron guide configuration; - Improvements made to enable easier future guide...Go to contribution page
-
Mr Stewart Pullen (ANSTO)29/11/2017, 17:16Project management of instrument buildsPosterThis poster will outline the progress to date on the transfer of the BioRef (SPATZ) reflectometer from the Helmholtz-Zentrum Berlin to ANSTO. It will also outline work to be done to complete the transfer by September 2018.Go to contribution page
-
Mr Merv Perry (ANSTO)29/11/2017, 17:22In 2007 ACNS (formally known as The Bragg Institute) commissioned its first small angle instrument known as Quokka. Quokka has a fixed collimation tank of 20meters and a sample area gap of 960 mm to allow for a variety of sample environment equipment from superconducting magnets to simple 20 position sample changers. The challenge was to keep the distance from the sample environment...Go to contribution page
-
Mr Matt Bell (ANSTO)29/11/2017, 17:28Neutron Guides & ShieldingPosterHigher background on detectors compared to anticipated design levels? Persistent hot spots on detectors? Increased radiation levels? These are common aspects of a new instrument, and even an old instrument. The divergent beam exiting from a guide, or reflecting from a chopper, can create unwanted background, or damage neighbouring equipment. For instance, persistent hot spots and higher...Go to contribution page
-
Mr Guido Vehres (Forschungszentrum Jülich GmbH)29/11/2017, 17:34Instrument Electrical SystemsOral PresentationThe Powersupply system of the Neutron Spin-Echo Spectrometer at the FRM-II F. Beule, T. Kozielewski, M. Monkenbusch, G. Vehres Jülich Centre for Neutron Science, Forschungszentrum Jülich GmbH, Jülich, Germany O. Holderer, S. Pasini Jülich Centre for Neutron Science, Forschungszentrum Jülich GmbH, Outstation at MLZ, Garching, Germany A Neutron Spin-Echo Spectrometer (NSE)...Go to contribution page
-
Mr Sebastian Williams (ANSTO)29/11/2017, 17:40The backscattering instrument managed by ANSTO called Emu was built with two neutron choppers. These choppers condition the neutron beam and typically spin at 2400rpm and 1200rpm respectively. They were supplied with an integrated vibration monitoring system. From late 2016, this system would occasionally trip, decreasing the availability of the instrument. This issue, coupled with the...Go to contribution page
-
Mr Wataru Kambara (J-PARC)29/11/2017, 17:46Materials and Life Science Experimental Facility (MLF) at J-PARC is a pulsed neutron facility. The accelerators have delivered a proton beam at 25 pps to a mercury neutron producing target. MLF has over 20 instruments and over 50 neutron choppers. Neutron Choppers are important devices that remove unwanted energy components from the pulsed neutron beam. We have been improving durability and...Go to contribution page
-
Dr Deon Marais (The South African Nuclear Energy Corporation (Necsa) SOC Limited)29/11/2017, 17:52Neutron radiography has been conducted at the SAFARI-1 research reactor since the early 1970’s. Digital neutron radiography commenced in 1996 and a 3D tomography capability was installed in 2003. Major deficiencies regarding corrosion of water cooling pipes of the internal collimator as well as shielding and control infrastructure were identified to be addressed in the design of new...Go to contribution page
-
Mr Andrew Eltobaji (ANSTO)29/11/2017, 17:58Operations, User Support & MaintenanceOral PresentationANSTO is planning to replace the Cold Neutron Source (CNS) at the end of its design life. The project has a number of challenges due to the activity of the components. Working to ALARA principles and to minimise the reactor shutdown duration, a number of specialised tools and processes are being developed. The topics that will be discussed in this presentation include the components to be...Go to contribution page
-
Mr Daniel Bartlett (ANSTO)29/11/2017, 18:04Operations, User Support & MaintenanceNagios, a free and open source computer-software application that monitors systems, networks and infrastructure[1], was configured to monitor the health of common industrial devices. The ACNS has 14 neutron beam instruments which employ various industrial electronic components such as: Galil controllers, Rockwell programmable logic controllers, Pilz safety systems and many others. Monitoring...Go to contribution page
-
Stan Lee (Australian Nuclear Science Technology Organisation)29/11/2017, 18:10In order to complete and complement the neutron instruments, Australian Centre for Neutron Scattering procures and commissions a continuously evolving suite of sample environment equipment, able to determine and manipulate the physical conditions under which a neutron scattering experiment is performed. The sample environment equipment, therefore, plays a crucial role in the success of an...Go to contribution page
-
Mr Kendal Bingöl (JCNS / Forschungszentrum Jülich)29/11/2017, 18:16Neutron beam polarization devicesOral PresentationThe neutron reflectometer MARIA with polarization analysis is dedicated for the investigation of thin interfaces like magnetic layered structures down to the monolayer scale and/or lateral structures. To maximize the signal to noise ratio the background scattering has to be kept as low as possible. Therefore the flight path of the neutrons before and after the sample should be not in air but...Go to contribution page
-
Mr David Brodrick (European Spallation Source ERIC)29/11/2017, 18:22Motion and instrument controls systemsOral PresentationThe European Spallation Source ERIC (ESS) are actively developing fifteen neutron instruments, the first of which will be ready for routine user operation by 2023. Although the instruments are being developed by many partner institutions, a common controls framework will be used for all instruments in the ESS instrument suite. This presentation will provide a brief overview of the controls...Go to contribution page
-
Mr Mark New (Asnto), Mr Tai Nguyen (Ansto)29/11/2017, 18:28With the major rise in commercial infrastructure works in recent years, the workload demands on the Kowari Residual Stress Instrument on industrial engineering components has also increased significantly. And while the increase in demand represents good news for the industry, the changes have also brought with it many new challenges. These challenges have demanded innovation from...Go to contribution page
-
Dr Tomohiro Kobayashi (RIKEN)29/11/2017, 18:34A compact neutron source by using a particle accelerator is a promising tool for practical material analysis, infrastructural diagnostics, nuclear detection, and medical treatment. We have been operating the neutron source RANS (RIKEN Accelerator-driven compact Neutron Source) with 7 MV proton LINAC and a beryllium target for 5 years and learned a lot about experiment, maintenance and safety...Go to contribution page
-
Mr Paul-Emmanuel Doege (JCNS-2, Forschungszentrum Jülich GmbH, D-52425 Jülich, Germany)29/11/2017, 18:40Neutron SourceOral PresentationNeutron supply for research is nowadays predominately based on spallation or fission. The High Brilliance neutron Source (HBS), currently under development at Forschungszentrum Jülich, will use protons or deuterons from an accelerator in the 10 MeV to 50 MeV range, shot on a low Z-material in order to produce neutrons. The HBS is optimized to be highly cost efficient and scalable. Medium flux...Go to contribution page
-
Mr Harald Kleines (Forschungszentrum Juelich)29/11/2017, 18:46For the readout of multi wire proportional chambers (MWPC), Forschungszentrum Jülich has developed a CompactPCI module based on the GPX TDC ASIC from acam messelectronic gmbh. Originally designed for X-Ray spectroscopy at the plasma physics tokamak TEXTOR, recently it has been integrated into the DAQ electronics of the neutron reflectometer MARIA. For the integration into the MARIA instrument...Go to contribution page